This Shift Kit fits 2013 and newer GM vehicles equipped with GEN 2 6T30, 6T40, 6T45 and 6T50 automatic transmission. These transmissions often come in with complaints of soft or flare up on shifts, burned friction plates, TCC slip as well as various solenoids and gear ratio codes. This kit does not fit GEN 1 units.
These complaints are often the result of wear at the actuator feed limit (AFL) valve. The purpose of the AFL valve is to limit the pressure going to the solenoids. The AFL valve spring is calibrated to prevent the solenoid feed pressure from exceeding a predetermined PSI, no matter what main line pressure is. This is necessary to prevent more fluid from being fed to the solenoids than they can effectively regulate and limit what max line pressure output is. If the pressure feeding the solenoids is too high or too low, their output will also be too high or too low. As a result, shift quality complaints and codes can occur along with low or high main line pressure.
The other source of these complaints is at the spring end of the pressure regulator valve. This is the EPC boost area of the valve. When bore or valve wear occurs here, it causes a loss of EPC boost signal oil. The end result is lazy or low-pressure boost response, low line pressure, clutch slippage, solenoid performance and gear ratio codes. Lastly, the TCC regulator valve bore wears out causing the TCC slip problems and codes.
Features and benefits:
This TransGo Shift Kit includes an oversized AFL valve. The new valve is oversize , therefore you will need a tool-kit to ream the bore. This universal tool-kit works for all GEN2 6F35, 6T30, 6T40, 6T45, 6T50, 6T70, 6T75 and 6T80 transmissions.
A new drop-in hardened steel TCC regulator valve that has re-positioned longer lands and incorporates a groove where a scarf cut seal is fitted so that it seals in the original worn bore. Lastly, a new design PR valve with longer lands restores the function and reliability of the pressure regulator system.
GEN 2 have no pressure switches in the TEHCM.
This Shift Kit fits 2013 and newer GM vehicles equipped with GEN 2 6T30, 6T40, 6T45 and 6T50 automatic transmission. These transmissions often come in with complaints of soft or flare up on shifts, burned friction plates, TCC slip as well as various solenoids and gear ratio codes. This kit does not fit GEN 1 units.
These complaints are often the result of wear at the actuator feed limit (AFL) valve. The purpose of the AFL valve is to limit the pressure going to the solenoids. The AFL valve spring is calibrated to prevent the solenoid feed pressure from exceeding a predetermined PSI, no matter what main line pressure is. This is necessary to prevent more fluid from being fed to the solenoids than they can effectively regulate and limit what max line pressure output is. If the pressure feeding the solenoids is too high or too low, their output will also be too high or too low. As a result, shift quality complaints and codes can occur along with low or high main line pressure.
The other source of these complaints is at the spring end of the pressure regulator valve. This is the EPC boost area of the valve. When bore or valve wear occurs here, it causes a loss of EPC boost signal oil. The end result is lazy or low-pressure boost response, low line pressure, clutch slippage, solenoid performance and gear ratio codes. Lastly, the TCC regulator valve bore wears out causing the TCC slip problems and codes.
Features and benefits:
This TransGo Shift Kit includes an oversized AFL valve. The new valve is oversize , therefore you will need a tool-kit to ream the bore. This universal tool-kit works for all GEN2 6F35, 6T30, 6T40, 6T45, 6T50, 6T70, 6T75 and 6T80 transmissions.
A new drop-in hardened steel TCC regulator valve that has re-positioned longer lands and incorporates a groove where a scarf cut seal is fitted so that it seals in the original worn bore. Lastly, a new design PR valve with longer lands restores the function and reliability of the pressure regulator system.
Corrects/Prevents/Reduces:
Includes:
TransGo Installation Instructions